Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Diagnostics (Basel) ; 13(9)2023 May 07.
Article in English | MEDLINE | ID: covidwho-2317286

ABSTRACT

BACKGROUND: Few studies have compared COVID-19 patients from different waves. This study aims to conduct a clinical and morphological analysis of patients who died from COVID-19 during four waves. METHODS: The study involved 276 patients who died from COVID-19 during four waves, including 77 patients in the first wave, 119 patients in the second wave, and 78 patients in the third wave. We performed a histological examination of myocardium samples from autopsies and additionally analyzed the samples by PCR. We conducted immunohistochemistry of the myocardium for 21 samples using antibodies against CD3, CD45, CD8, CD68, CD34, Ang1, VWF, VEGF, HLA-DR, MHC1, C1q, enteroviral VP1, and SARS-CoV-2 spike protein. We also did immunofluorescent staining of three myocardial specimens using VP1/SARS-CoV-2 antibody cocktails. Further, we ran RT-ddPCR analysis for 14 RNA samples extracted from paraffin-embedded myocardium. Electron microscopic studies of the myocardium were also performed for two samples from the fourth wave. RESULTS: Among the 276 cases, active myocarditis was diagnosed in 5% (15/276). Of these cases, 86% of samples expressed VP1, and individual cells contained SARS-CoV-2 spike protein in 22%. Immunofluorescence confirmed the co-localization of VP1 and SARS-CoV-2 spike proteins. ddPCR did not confidently detect SARS-CoV-2 RNA in the myocardium in any myocarditis cases. However, the myocardium sample from wave IV detected a sub-threshold signal of SARS-CoV-2 by qPCR, but myocarditis in this patient was not confirmed. Electron microscopy showed several single particles similar to SARS-CoV-2 virions on the surface of the endothelium of myocardial vessels. A comparison of the cardiovascular complication incidence between three waves revealed that the incidence of hemorrhage (48 vs. 24 vs. 17%), myocardial necrosis (18 vs. 11 vs. 4%), blood clots in the intramural arteries (12 vs. 7 vs. 0%), and myocarditis (19 vs. 1 vs. 6%) decreased over time, and CD8-T-killers appeared. Immunohistochemistry confirmed the presence of endotheliitis in all 21 studied cases. CONCLUSIONS: This study compared myocardial damage in patients who died during three COVID-19 waves and showed a decrease in the incidence of endotheliitis complications (thrombosis, hemorrhage, necrosis) and myocarditis over time. However, the connection between myocarditis and SARS-CoV-2 infection remains unproven.

2.
Med Phys ; 2022 Aug 11.
Article in English | MEDLINE | ID: covidwho-2287223

ABSTRACT

BACKGROUND: Auxiliary diagnosis and monitoring of lung diseases based on lung ultrasound (LUS) images is important clinical research. A-line is one of the most common indicators of LUS that can offer support for the assessment of lung diseases. A traditional A-line detection method mainly relies on experienced clinicians, which is inefficient and cannot meet the needs of these areas with backward medical level. Therefore, how to realize the automatic detection of A-line in LUS image is important. PURPOSE: In order to solve the disadvantages of traditional A-line detection methods, realize automatic and accurate detection, and provide theoretical support for clinical application, we proposed a novel A-line detection method for LUS images with different probe types in this paper. METHODS: First, the improved Faster R-CNN model with a selection strategy of localization box was designed to accurately locate the pleural line. Then, the LUS image below the pleural line was segmented for independent analysis excluding the influence of other similar structures. Next, image-processing methods based on total variation, matched filter, and gray difference were applied to achieve the automatic A-line detection. Finally, the "depth" index was designed to verify the accuracy by judging whether the automatic measurement results belong to corresponding manual results (±5%). In experiments, 3000 convex array LUS images were used for training and validating the improved pleural line localization model by five-fold cross validation. 850 convex array LUS images and 1080 linear array LUS images were used for testing the trained pleural line localization model and the proposed image-processing-based A-line detection method. The accuracy analysis, error statistics, and Harsdorff distance were employed to evaluate the experimental results. RESULTS: After 100 epochs, the mean loss value of training and validation set of improved Faster R-CNN model reached 0.6540 and 0.7882, with the validation accuracy of 98.70%. The trained pleural line localization model was applied in the testing set of convex and linear probes and reached the accuracy of 97.88% and 97.11%, respectively, which were 3.83% and 8.70% higher than the original Faster R-CNN model. The accuracy, sensitivity, and specificity of A-line detection reached 95.41%, 0.9244%, 0.9875%, and 94.63%, 0.9230%, and 0.9766% for convex and linear probes, respectively. Compared to the experienced clinicians' results, the mean value and p value of depth error were 1.5342 ± 1.2097 and 0.9021, respectively, and the Harsdorff distance was 5.7305 ± 1.8311. In addition, the accumulated accuracy of the two-stage experiment (pleural line localization and A-line detection) was calculated as the final accuracy of the whole A-line detection system. They were 93.39% and 91.90% for convex and linear probes, respectively, which were higher than these previous methods. CONCLUSIONS: The proposed method combining image processing and deep learning can automatically and accurately detect A-line in LUS images with different probe types, which has important application value for clinical diagnosis.

3.
Ultrasound Med Biol ; 48(5): 945-953, 2022 05.
Article in English | MEDLINE | ID: covidwho-1740249

ABSTRACT

Recent research has revealed that COVID-19 pneumonia is often accompanied by pulmonary edema. Pulmonary edema is a manifestation of acute lung injury (ALI), and may progress to hypoxemia and potentially acute respiratory distress syndrome (ARDS), which have higher mortality. Precise classification of the degree of pulmonary edema in patients is of great significance in choosing a treatment plan and improving the chance of survival. Here we propose a deep learning neural network named Non-local Channel Attention ResNet to analyze the lung ultrasound images and automatically score the degree of pulmonary edema of patients with COVID-19 pneumonia. The proposed method was designed by combining the ResNet with the non-local module and the channel attention mechanism. The non-local module was used to extract the information on characteristics of A-lines and B-lines, on the basis of which the degree of pulmonary edema could be defined. The channel attention mechanism was used to assign weights to decisive channels. The data set contains 2220 lung ultrasound images provided by Huoshenshan Hospital, Wuhan, China, of which 2062 effective images with accurate scores assigned by two experienced clinicians were used in the experiment. The experimental results indicated that our method achieved high accuracy in classifying the degree of pulmonary edema in patients with COVID-19 pneumonia by comparison with previous deep learning methods, indicating its potential to monitor patients with COVID-19 pneumonia.


Subject(s)
COVID-19 , Pulmonary Edema , Respiratory Distress Syndrome , COVID-19/complications , COVID-19/diagnostic imaging , Humans , Lung/diagnostic imaging , Pulmonary Edema/complications , Pulmonary Edema/diagnostic imaging , Respiratory Distress Syndrome/complications , Respiratory Distress Syndrome/diagnostic imaging , Ultrasonography
4.
Biomed Signal Process Control ; 75: 103561, 2022 May.
Article in English | MEDLINE | ID: covidwho-1670239

ABSTRACT

Coronavirus disease 2019 (COVID-19) pneumonia has erupted worldwide, causing massive population deaths and huge economic losses. In clinic, lung ultrasound (LUS) plays an important role in the auxiliary diagnosis of COVID-19 pneumonia. However, the lack of medical resources leads to the low using efficiency of the LUS, to address this problem, a novel automated LUS scoring system for evaluating COVID-19 pneumonia based on the two-stage cascaded deep learning model was proposed in this paper. 18,330 LUS images collected from 26 COVID-19 pneumonia patients were successfully assigned scores by two experienced doctors according to the designed four-level scoring standard for training the model. At the first stage, we made a secondary selection of these scored images through five ResNet-50 models and five-fold cross validation to obtain the available 12,949 LUS images which were highly relevant to the initial scoring results. At the second stage, three deep learning models including ResNet-50, Vgg-19, and GoogLeNet were formed the cascaded scored model and trained using the new dataset, whose predictive result was obtained by the voting mechanism. In addition, 1000 LUS images collected another 5 COVID-19 pneumonia patients were employed to test the model. Experiments results showed that the automated LUS scoring model was evaluated in terms of accuracy, sensitivity, specificity, and F1-score, being 96.1%, 96.3%, 98.8%, and 96.1%, respectively. They proved the proposed two-stage cascaded deep learning model could automatically score an LUS image, which has great potential for application to the clinics on various occasions.

5.
IEEE Trans Ultrason Ferroelectr Freq Control ; 68(7): 2507-2515, 2021 07.
Article in English | MEDLINE | ID: covidwho-1288239

ABSTRACT

As being radiation-free, portable, and capable of repetitive use, ultrasonography is playing an important role in diagnosing and evaluating the COVID-19 Pneumonia (PN) in this epidemic. By virtue of lung ultrasound scores (LUSS), lung ultrasound (LUS) was used to estimate the excessive lung fluid that is an important clinical manifestation of COVID-19 PN, with high sensitivity and specificity. However, as a qualitative method, LUSS suffered from large interobserver variations and requirement for experienced clinicians. Considering this limitation, we developed a quantitative and automatic lung ultrasound scoring system for evaluating the COVID-19 PN. A total of 1527 ultrasound images prospectively collected from 31 COVID-19 PN patients with different clinical conditions were evaluated and scored with LUSS by experienced clinicians. All images were processed via a series of computer-aided analysis, including curve-to-linear conversion, pleural line detection, region-of-interest (ROI) selection, and feature extraction. A collection of 28 features extracted from the ROI was specifically defined for mimicking the LUSS. Multilayer fully connected neural networks, support vector machines, and decision trees were developed for scoring LUS images using the fivefold cross validation. The model with 128×256 two fully connected layers gave the best accuracy of 87%. It is concluded that the proposed method could assess the ultrasound images by assigning LUSS automatically with high accuracy, potentially applicable to the clinics.


Subject(s)
COVID-19/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Lung/diagnostic imaging , Neural Networks, Computer , Ultrasonography/methods , Adult , Aged , Female , Humans , Male , Middle Aged , SARS-CoV-2
6.
IEEE Sens J ; 21(9): 11084-11093, 2021 May 01.
Article in English | MEDLINE | ID: covidwho-1132775

ABSTRACT

Coronavirus Disease 2019 (COVID-19) has spread all over the world since it broke out massively in December 2019, which has caused a large loss to the whole world. Both the confirmed cases and death cases have reached a relatively frightening number. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the cause of COVID-19, can be transmitted by small respiratory droplets. To curb its spread at the source, wearing masks is a convenient and effective measure. In most cases, people use face masks in a high-frequent but short-time way. Aimed at solving the problem that we do not know which service stage of the mask belongs to, we propose a detection system based on the mobile phone. We first extract four features from the gray level co-occurrence matrixes (GLCMs) of the face mask's micro-photos. Next, a three-result detection system is accomplished by using K Nearest Neighbor (KNN) algorithm. The results of validation experiments show that our system can reach an accuracy of 82.87% (measured by macro-measures) on the testing dataset. The precision of Type I 'normal use' and the recall of type III 'not recommended' reach 92.00% and 92.59%. In future work, we plan to expand the detection objects to more mask types. This work demonstrates that the proposed mobile microscope system can be used as an assistant for face mask being used, which may play a positive role in fighting against COVID-19.

SELECTION OF CITATIONS
SEARCH DETAIL